|   Home  |  About  |  Products and Services  |  Vickers HTM  |  Library  |  Contact  |
Vickers Hardness Testing Machines
 

As successors to the inventors of the Vickers hardness test, UK Calibrations are probably the best company in the world to specify and supply Vickers hardness machines, and as authorised agents of Wolpert Wilson, can supply a full range of modern and accurate Vickers hardness testing equipment.

Wolpert Wilson Vickers / Knoop hardness testers are widely used for determining the hardness of small precision parts, thin material or wire, coatings, and performing case depth determinations (CHD, EHT, NHT) UK Calibrations also offer software-based measurement packages designed to increase productivity, accuracy and efficiency through automating the measurement and/or the stage navigation process.

UK Calibrations also supply a range of Universal hardness testers with Vickers function.


Vickers Series 430 / 432 / 450 / 452 SVA/SVD Micro/Macro hardness testers for HV0.3 to HV50

The Series 400 Vickers and Knoop testers are versatile, user-friendly, and provide an affordable, reliable solution for accurate Vickers and Knoop hardness scale testing, both for quality assurance or metallurgical research. The 400 Series is available with manual or automatic turrets and comes equipped with crisp optics that have a total magnification of 100x and 400x for microhardness and 100x and 200x for macro Vickers readings. The systems feature eight dial selectable test forces ranging from 10g to 50kg (see table). For easy sample mounting, models are equipped with a 100x100mm precision XY stage with 25mm movement in each direction.

  • HV0.3 up to HV50, and HK0.3 to HK50
  • Direct load selection automatically changes in test settings
  • Solid eyepiece with analogue reading or automatic encoder
  • Two optical paths,for eyepiece and ccd-camera
  • Manual or motorised turret operation enabling automated test cycle by the push of start button
  • Smooth XY-stage 100x100mm, travel 25x25mm, motorised versions available
  • Direct load selection automatically changes in test settings
  • Hardness diagonals, value, statistics and conversions on back-lit display
  • Language selection
  • Built-in thermal printer on all models MVD/SVD
  • Adjustable halogen light source, with green or blue filter, for crisp images
  • WHV-CCD system for semi and fully automatic traverse and pattern testing by pc support and motorised XY stage
Model 430-SVA 430-SVD 432-SVA 432-SVD 450-SVA 450-SVD 452-SVA 452-SVD
Vickers Scales HV0.3, HV0.5, HV1, HV3, HV5, HV10, HV20, HV30 HV0.3, HV0.5, HV1, HV3, HV5, HV10, HV20, HV30, HV50
Test Loads 0.3, 0.5,1, 3, 5, 10, 20, 30 0.3, 0.5,1, 3, 5, 10, 20, 30, 50
Turret Manual Motorised Manual Motorised
Encoder Analogue Digital Analogue Digital Analogue Digital Analogue Digital
Resolution 0.5µm 0.1µm 0.5µm 0.1µm 0.5µm 0.1µm 0.5µm 0.1µm
Built-in printer, RS232 serial Yes Yes Yes Yes
Statistics Yes Yes Yes Yes
Conversion Brinell, Tensile, Rockwell, Superficial Rockwell Yes Yes Yes Yes
Vickers hardness tester 452-SVD

All Models
Test force selection Dial
Accuracy Conforms to EN ISO 6507, ASTM and JIS
Load Control Automatic loading, Dwell and unloading
Load Duration 5 to 99 sec.
Eyepiece magnification 10x
Objectives 10x, 40x, (for MVD 20x, 50x, 60x optional)
Total magnification 100x, 200x
Measuring range 100x: 800µm , 200x;400µm
Display Length of diagonal, hardness converted value, test force N, kg
Accuracy Conforms to EN-ISO 6508, ASTM E-18 and JIS
Hardness value 5 digit
Maximum specimen height 210mm
Depth from the centre line 160mm
Anvil Flat anvil 63mm diameter
Specimen access External surfaces, Cylindrical specimens down to 3 mm diameter
Operating temperature Range: 10 to 38 degrees Celsius
Humidity 10% to 90% non condensing
Dimensions (LxWxH) 566mm x 300mm x 710mm
Power supply 220 Vac 50Hz

Model 452-SVD shown. Click the image to enlarge. Download the .pdf brochure, talk to an expert at UK Calibrations about this, other machines or any aspect of hardness testing.


High-end Vickers/Knoop testers ranging from HV0.005 to HV50

The Tukon 2100 tester is ideal for quality assurance, quality control, research and development and metallurgical departments. It can be used to monitor hardness during development, fabrication, heat treatment and the performance analysis of a variety of products and components. The WILSON design team has used its rich experience to create the industry standard for accuracy and repeatability in hardness testing. The Series 2100 closed-loop control electronics system instantly measures and controls the force applied to the specimen, resulting in unmatched accuracy. State-of-the art sensors and closed loop control technology combine to make the Tukon 2100 the most precise, consistent and accurate instrument for hardness testing. The system is build around precision force sensors and electromechanical drive systems to produce the most repeatable, error-free and accurate test results.

  • Indenter mounted directly on load cell - improves accuracy and repeatability of results
  • Exclusive turret design - choose from a selection of indenters, load cells and objectives to suit your application
  • Easy to use, adjustable, ergonomic, backlit user interface
  • Precision X-Y stage for precise positioning of samples
  • Test control panel with high speed jog, ultra fine focus and light control
Model 2100 Low load 2101 high load 2102 low and high load
Vickers Scales HV0.01, HV 0.025, HV0.1, HV0.3, HV0.5, HV1 HV0.3, HV0.5, HV1, HV3, HV5, HV10, HV20, HV30, HV50 from HV0.01 to HV50
Test Loads 10, 25, 50, 100, 200, 300, 500 , 1000gf 0.3, 0.5,1, 3, 5, 10, 20, 30, 50 kgf from 10gf to 50kgf
Vickers hardness tester 2100

All Models
Test force selection Automatic
Accuracy Conforms to EN ISO 6507, ASTM and JIS +/- 1.5% <200g, +/-1% >200g
Load Control Automatic loading, Dwell and unloading
Load Duration 0.1 to 99 sec (ASTM E384 10 sec)
Eyepiece Dual line filar eyepiece with 10x Digital Encoder
Objectives 4x, 10x, 20x, 40x, 50x, 60x, 80x, 100x
Total magnification 40x, 100x, 200x, 400x, 500x, 600x, 800x, 1000x
Measuring range 100x: 800µm , 200x;400µm
Display Length of diagonal, hardness converted value, test force N, kg
Hardness value 5 digit
Maximum specimen height 210mm
Depth from the centre line 165mm
optional XY stage 90mm square
Operating temperature Range: 10 to 38 degrees Celsius
Humidity 10% to 90% non condensing
Dimensions (LxWxH) 952mm x 330mm x 597mm
Power supply 220 Vac 50Hz

Model 2100 Tukon shown. Click the image to enlarge. Download the .pdf brochure, talk to an expert at UK Calibrations about this, other machines or any aspect of hardness testing.


Minuteman ELT Video and Automated Hardness Measurement

UK Calibrations can now offer the Minuteman ELT, a computerised automatic test system software based measurement package designed to increase productivity, accuracy and efficiency by automating the measurement and / or the stage navigation process. If you are looking for a way to lower testing costs while maintaining strict compliance with ISO/ASTM standards, DV-TESTOR can provide you with a system to meet your requirements. We offer four distinctive software levels from basic to full automatic testing.

Contact a friendly expert now, to discuss the benefits and applications of the Minuteman ELT system.

Vickers computerised test system Minuteman ELT
  • Camera based measurements This PC based video system reduces operator errors and fatigue associated with traditional Microindentation measurements.
  • User friendly software, lets you setup complex case depth and analysis patterns and save for repetitive use.
  • Data evalution, Save results within the data base or print directly from the application.
  • Easy upgrade
  • Automatic pattern measurements, Easily address complexities of case depth, multiple line patterns and any application requiring production testing.
  • Suitable for all WOLPERT Vickers and Micro-Vickers hardness testers

Click the image to enlarge. Download the .pdf brochure, talk to an expert at UK Calibrations about this, other machines or any aspect of hardness testing.


Links
|   Home  |  About  |  Products and Services  |  Vickers HTM  |  Library  |  Contact  |  Privacy  |